Randy Shrimplin's avatar

We need to remember that while proper torque is important, those tables were engineered on static (non-mobile) systems. RV are subjected to major vibrations so all connections should be checked regularly. I wonder if some kind of thread locker product might be a best practice for RV's ?????

Expand full comment
Scott Harris's avatar

My rules for bus bars: (also applies to battery connections).

1. Make sure that the bus bars are rated for at least the amount of current you expect to ever have going through them. Use UL rated bus bars and not home made ones.

2. Never place a washer between the wire terminal and the bus bar. The wire terminal and bus bar should have a direct surface to surface contact. The flat washer should go on top of the terminal and the lock washer on top of that.

3. If you have multiple terminals connected to a single stud, have the largest (highest current) wire on the bottom and the smaller ones on top. Never stack more that 4 terminals on one stud.

4. Make sure that no insulation, dirt, or corrosion gets between the surfaces.

5. Where possible, place the biggest current source (the battery) in the middle of the bus bar and the biggest load (usually the inverter) right next to to the battery. This way the largest currents don't have to travel from one end of the bus bar to the other.

6. With stainless steel hardware it is best practice to place a tiny bit of dielectric grease on the threads to prevent galling.

7. Always use tin plated copper (marine rated) terminals in areas that will be exposed to the elements or possibility of corrosion (such as lead acid batteries).

Expand full comment
9 more comments...